Skip to content

Interlogix NX-4V2 / NX-6V2 with GT/GT+/GET quick setup

Short wiring and programming steps to connect the GT/GT+/GET communicator to Interlogix NX-4V2, Interlogix NX-6V2 panels using KeyBus, then enroll the system in Protegus2. Use this alongside the full manuals for all other settings. (Terminal labels differ slightly between GT/GT+/GET, but the connections are the same.)

Caution

Install and service only by qualified personnel. Disconnect power before wiring. Unauthorized changes void warranty.

1. Prerequisites

  1. GT/GT+/GET firmware 1.21, SIM inserted, PIN disabled, data plan active.
  2. Interlogix NX-4V2 / NX-6V2 panel with keypad access (installer code available).
  3. CMS account number if reporting to CMS.
  4. Protegus2 company/installer account and communicator IMEI.

2. Wiring

Follow the schematic below to connect the communicator to the panel:

GT/GT+/GET terminal Interlogix panel Notes
+12V DC/-12V DC POS/COM Power the communicator
DATA DATA KeyBus

GT+ Interlogix NX-4V2 prijungimo schema ENG 2025 12 31

GT+ Interlogix NX-6V2 prijungimo schema ENG 2025 12 31

3. Programming the Interlogix NX-4V2, Interlogix NX-6V2 Alarm Panel via the LCD Keypad

Using the control panel‘s keypad enter these sections and set them as described:

Enable Contact ID reporting

LCD keypad Keypad Entry Action Description
System ready *89713 Enter programming mode
Enter device address 0# To go to main panel programming menu
Enter location 4# To go to “Phone1 events reported” toggle menu
Loc#4 Seg#1 12345678* All toggle options should be enabled. * to save and go to next menu
Loc#4 Seg#2 12345678* All toggle options should be enabled. * to save and go back.
Enter location 23# To go to “Partition features” menu.
Loc#23 Seg#1 ** Press * twice to go to section 3 toggle options menu.
Loc#23 Seg#3 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Enter location 37# To go to “Siren and system supervision” menu.
Loc#37 Seg#1 ** Press * twice to go to segment 3 toggle options menu.
Loc#37 Seg#3 12345678* Segment 3. All toggle options should be enabled press * to save.
Loc#37 Seg#4 12345678*# Segment 4. All toggle options should be enabled press * to press and then # to save and # to go back to the main menu.
Enter location EXIT EXIT Press “EXIT” twice to exit programming mode.

4. Programming the Interlogix NX-4V2, Interlogix NX-6V2 Alarm Panel via the LED Keypad

Using the control panel’s keypad enter these sections and set them as described:

Enable Contact ID reporting

LCD keypad Keypad Entry Action Description
LEDs of Ready, Power steady ON *89713 Enter programming mode
Service LED blinks 0# To go to main panel programming menu
Service LED blinks, Armed LED steady ON 4# To go to “Phone1 events reported” toggle menu
All zone LEDs are ON 12345678* All toggle options should be enabled. * to save and go to next menu
All zone LEDs are ON 12345678* All toggle options should be enabled. * to save and go back.
Service LED blinks, Armed LED steady ON 23# To go to “Partition features and reporting selection” menu.
Service LED blinks, Ready LED steady ON ** Press * twice to go to section 3 toggle options menu.
Service LED blinks, Ready LED steady ON 12345678*# Segment 3. All toggle options should be enabled, press * to save and then # to save and # to go back to the main menu.
Service LED blinks, Armed LED steady ON 37# To go to “Siren and system supervision” menu.
Service LED blinks, Ready LED steady ON ** Press * twice to go to segment 3 toggle options menu.
Service LED blinks, Ready LED steady ON 12345678* Segment 3. All toggle options should be enabled press * to save.
Service LED blinks, Ready LED steady ON 12345678*# Segment 4. All toggle options should be enabled press * to press and then # to save and # to go back to the main menu.
Service LED blinks, Armed LED steady ON EXIT EXIT Press “EXIT” twice to exit programming mode.

5. Add system to Protegus2

Step 1. Tap Add new system. Add new system
Step 2. Enter the communicator IMEI, tap Next. Add new system
Step 3. Select security company. Add new system
Step 4. Choose Interlogix. Add new system
Step 5. Choose NX-4 (NX-6). Add new system
Step 6. Enter Object ID and Module ID, tap Next. Add new system
Step 7. Wait while data is written. Add new system
Step 8. Tap Add to Protegus2. Add new system
Step 9. Enter system Name, tap Next. Add new system
Step 10. Tap Skip. Add new system
Step 11. Tap on system. Add new system
Step 12. Wait 1 minute for completion and tap Transfer. Add new system
Step 13. Enter the e-mail of the user to whom the installer will transfer the system. Tap Transfer. Add new system
Step 14. The system will appear in Protegus on the user's phone. Add new system

Tip

After completing the setup and installation perform a system check:

  1. Create an event:
  • by arming/disarming the system with the control panel’s keypad.
  • by triggering a zone alarm when the security system is armed.
  1. Make sure that the event arrives to the CMS (Central Monitoring Station) and the Protegus2 app.