RL25 hardware receiver¶
RL25 is IPCom v5 delivered on dedicated, prevalidated hardware. It runs the Linux edition, and the web interface is largely the same as any other IPCom v5 Linux deployment — so the rest of this IPCom section describes how to operate it. This page covers what is specific to the hardware unit, including the one section RL25 has that other deployments do not.
Some material elsewhere in this section does not apply to RL25:
- The Windows
.exeaccess flow in Access and login. - The Windows column of the capability comparison in the overview.
- The server sizing and operating-system requirements in the overview. Those are for building your own Linux server; RL25 arrives with that work done.
- The General page describes a non-RL25 deployment, so it does not show the
Network settingssection covered below.
1. Form factors¶
| Variant | Description |
|---|---|
| RL25 Compact | Standalone unit |
| RL25 Rack | 19-inch rack-mounted unit |
Both variants run the same IPCom v5 software. This page describes both known form factors — confirm which is currently orderable with TRIKDIS sales.
2. What ships preconfigured¶
RL25 arrives with the platform installed, so you go straight to configuring the receiver rather than building a server. Compared with a Windows or Linux installation, the following are already done for you:
- Linux operating system installed and configured
- IPCom v5 installed
- SSD and RAM preinstalled
You do not install an operating system, prepare a server, or run an installer.
RL25 is sold licensed.
3. Front panel indicator¶
The unit has a single blue indicator, which shows only whether it is powered on. There are no separate indicators for network, reception or fault conditions. The unit reports its condition through the software instead — see Status and Logs.
4. Specifications¶
| Item | RL25 |
|---|---|
| Power supply | External supply, nominal 220 V AC mains in, DC 12 V 5 A out |
| Network interfaces | 2 × Ethernet RJ-45 |
| IP receiver | Yes |
| Event reception | TCP, UDP, COM, RS232 |
| Supervised objects | Up to 50,000 per 1 GB RAM |
| Management | Web browser over HTTP/HTTPS |
| Remote configuration and control | TrikdisConfig, API, Protegus 2 Cloud |
| Compatible devices | All TRIKDIS devices |
| Rack height | 2U (Rack variant) |
4.1 Event output¶
RL25 supports the full IPCom v5 output set. In the Outputs tab you choose an output Type and, for the types that carry CMS traffic, a Protocol.
Types: TCP, TCP Server, COM Port, JSON Server, Webhook.
Protocols: Surgard MLR2, Surgard MLR2 8, Surgard MLR2 No End, Surgard MLR2 Line with Account, SurgardMRL2000 CID, Monas 3, Ademco 685, Ademco 685 CID, SIA DC-09.
Writing events to a MySQL database is configured separately, under Database settings in the General tab — not in Outputs.
4.2 Environmental reference data¶
These are the computer manufacturer's figures for the machine inside the unit, not a tested rating for the assembled receiver with its external supply.
| Item | Manufacturer's figure |
|---|---|
| Operating temperature | −20 °C to +65 °C |
| Storage temperature | −20 °C to +75 °C |
| Operating humidity | 5–95 % RH, non-condensing |
The assembled RL25 has no validated environmental rating. Do not approve an installation on the strength of these numbers — for a cold, hot, humid or otherwise unconditioned location, confirm with TRIKDIS first.
5. Capabilities compared with other deployments¶
RL25 runs the Linux edition, so it carries the Linux feature set — including the Protegus 2 relay, which the Windows installation does not provide. See the capability comparison in the IPCom overview for the full table.
6. Connecting for the first time¶
Both Ethernet interfaces are identical and both use DHCP. No interface is dedicated to management — IPCom is reached at whatever address your DHCP server assigns, on the same TCP port whichever interface you use.
Before you begin:
- The unit needs DHCP to be reachable the first time. There is no alternative — no fixed fallback address, and no way in over a serial or direct connection. On a network without a DHCP server you cannot reach it at all.
- The unit is powered through an external supply, included with it. It takes nominal 220 V AC mains and delivers the DC 12 V, 5 A the receiver needs, so you do not provide a DC source yourself. Check the input voltage and frequency printed on the supply against your local mains, and check the cord and plug, before energising it. A power cable, a LAN cable and a rack bracket are normally supplied too; check against the packing list for your order.
- Connect the unit to your network with an Ethernet cable, using either interface.
- Apply power.
- Find the address assigned to the unit, from your router's or DHCP server's client list.
- Open
https://<address>:30003in a browser. TCP port30003is IPCom's default for HTTPS;8080is the default for HTTP. - Sign in — see Access and login.
Tip
Leaving the unit on a plain DHCP lease means its address can change when the lease is renewed, and the receiver moves without warning. Either reserve its address on your DHCP server, or give it a fixed address in Network settings.
The power supply is external — it sits outside the chassis, so allow for it when planning the installation.
7. Network settings¶
The General tab on an RL25 has a Network settings section that does not appear on Windows or self-installed Linux deployments. On those, the operating system is yours and TRIKDIS does not manage it; on RL25 the appliance owns the network configuration, so it is configured here.
Warning
Plan the change before you make it. Decide the address, prefix, gateway and DNS values in advance, confirm the new address is reachable from where you are working, and make sure you have another way onto the unit's network if it is not. Changing the settings of the interface you are connected through will drop your session.
You need an account with the network_settings permission. Each interface is listed by name with a DHCP toggle; turning DHCP off reveals the fixed-address fields:
| Field | Purpose |
|---|---|
IP address | The fixed address for this interface |
Prefix | Network prefix length, for example 24 for a 255.255.255.0 mask |
Gateway | Default gateway |
DNS 1, DNS 2 | Name servers |
After you apply a change, IPCom runs a verification step and reports whether it could confirm the unit on the new settings. Treat that as a signal, not a guarantee — confirm access yourself through the new address before you rely on it.
8. Restoring factory defaults¶
Restoring defaults is a software function, performed from within IPCom Control. There is no hardware reset button on the unit.
Warning
A restore returns IPCom to factory settings, so the configuration on the unit is lost. Do not run it on a receiver that is in service.
A restore does not touch the network interfaces. Whatever you set under Network settings — DHCP or a fixed address — survives it, so the unit keeps its address. IPCom itself returns to its default ports, which it reports as 8080 for HTTP and 30003 for HTTPS, so reconnect there if you had changed them.
9. After the first login¶
Work through these in order to get a new receiver into service:
- Status — confirm the unit is healthy and reachable.
- General — review API and database options, and configure them if your deployment needs them.
- Receivers — define the receiver lines that accept device events.
- Outputs — route events to your monitoring software.
- Users — create named operator accounts for daily work, and reserve
administratorfor break-glass use.
Review Networking and firewall before exposing the unit beyond a trusted network.
10. Related pages¶
- IPCom v5 overview — deployment variants, capacity and hardware requirements
- Access and login — reaching the web interface
- Glossary — field and routing terminology