Innerrange Integriti with GT/GT+/GET quick setup¶



Short wiring and programming steps to connect the GT/GT+/GET communicator to an Innerrange Integriti panel using TTL Port-0, then enroll the system in Protegus2. Use this alongside the full manuals for all other settings. (Terminal labels differ slightly between GT/GT+/GET, but the connections are the same.)
Caution
Install and service only by qualified personnel. Disconnect power before wiring. Unauthorized changes void warranty.
1. Prerequisites¶
- GT/GT+/GET firmware 1.21, SIM inserted, PIN disabled, data plan active.
- Innerrange Integriti panel with firmware version 19.1.0.36608 or higher.
- Innerrange professional software version 19.1.0.15396 or higher.
- Inner Range cable, part number
INTG-996795. - CMS account number if reporting to CMS.
- Protegus2 company/installer account and communicator IMEI.
2. Wiring¶
Follow the schematic below to connect the communicator to the panel:
| GT/GT+/GET terminal | Innerrange Integriti panel | Notes |
|---|---|---|
| +12V DC | +DET | +13V supply |
| -12V DC | GND 5 | TTL Port-0 ground |
| CLK | Rx 3 | TTL Port-0 |
| DATA | Tx 2 | TTL Port-0 |

3. Programming the Innerrange Integriti Alarm Panel¶
- Make sure the Innerrange Integriti panel firmware is 19.1.0.36608 or higher and the professional software version is 19.1.0.15396 or higher.
- In the Integriti configuration program, specify the Trikdis communication protocol.
- Set the reporting data format to Contact ID.
- Configure the panel port connected to the communicator as TTL Port-0 with settings 19200, 8, N, 1.
- Save the settings and exit the program.
4. Add system to Protegus2¶
Step 1. Tap Add new system.
Step 2. Enter the communicator IMEI, tap Next.
Step 3. Select security company.
Step 4. Choose Innerrange.
Step 5. Choose Integriti.
Step 6. Enter Object ID and Module ID, tap Next.
Step 7. Wait while data is written.
Step 8. Tap Add to Protegus2.
Step 9. Enter system Name, tap Next.
Step 10. Tap Skip.
Step 11. Tap on system.
Step 12. Wait 1 minute for completion and tap Transfer.
Step 13. Enter the e-mail of the user to whom the installer will transfer the system. Tap Transfer.
Step 14. The system will appear in Protegus on the user's phone.
5. System check¶
Tip
After completing the setup and installation perform a system check:
- Create an event:
- by arming/disarming the system with the control panel's keypad.
- by triggering a zone alarm when the security system is armed.
- Make sure that the event arrives to the CMS (Central Monitoring Station) and the Protegus2 app.